Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 184

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Regulatory implementation of the occupational equivalent dose limit for the lens of the eye and underlying relevant efforts in Japan

Yokoyama, Sumi*; Hamada, Nobuyuki*; Tsujimura, Norio; Kunugita, Naoki*; Nishida, Kazutaka*; Ezaki, Iwao*; Kato, Masahiro*; Okubo, Hideki*

International Journal of Radiation Biology, 99(4), p.604 - 619, 2023/04

 Times Cited Count:1 Percentile:22.69(Biology)

In April 2011, the International Commission on Radiological Protection recommended reducing the occupational equivalent dose limit for the lens. Such a new occupational lens dose limit has thus far been implemented in many countries, and there are extensive discussions toward its regulatory implementation in other countries. In Japan, discussions in the Japan Health Physics Society (JHPS) began in April 2013 and in Radiation Council in July 2017, and the new occupational lens dose limit was implemented into regulation in April 2021. To share our experience, we have published a series of papers summarizing situations in Japan: the first paper based on information available by early 2017, and the second paper by early 2019. This paper (our third paper of this series) aims to review updated information available by mid-2022, such as regarding regulatory implementation of the new occupational lens dose limit, recent discussions by relevant ministries based on the opinion from the council, establishment process of safety and health management systems, the JHPS guidelines on lens dose monitoring and radiation safety, voluntary countermeasures of the licensees, development of lens dose calibration method, and recent studies on exposure of the lens in nuclear workers and biological effect on the lens.

Journal Articles

External dose estimation for wild animals using ESR spectroscopy

Oka, Toshitaka; Takahashi, Atsushi*

Hoshasen Kagaku (Internet), (110), p.13 - 19, 2020/10

The article depicts how to estimate the external exposure dose for wild animals using electron spin resonance (ESR) spectroscopy. The relationship between the CO$$_{2}$$ radical intensity and the absorbed dose, that is, dose response curve of tooth enamel of Japanese macaque was observed, and the detection limit of our method was estimated. The estimated detection limit of 33.5 mGy is comparable to the previously reported detection limit for human molar teeth. The external exposure dose for seven wild Japanese macaques captured in Fukushima prefecture were examined using this dose response curve. The estimated external exposure dose were ranged between 45 mGy to 300 mGy.

Journal Articles

Conversion factor from dosemeter reading to air kerma for nuclear worker using anthropomorphic phantom for further conversion from air kerma to organ-absorbed dose

Furuta, Hiroshige*; Tsujimura, Norio; Nishide, Akemi*; Kudo, Shinichi*; Saigusa, Shin*

Radiation Protection Dosimetry, 189(3), p.371 - 383, 2020/05

 Times Cited Count:4 Percentile:45.45(Environmental Sciences)

Journal Articles

Accuracy check of Monte Carlo simulation in particle therapy using gel dosimeters

Furuta, Takuya

Igaku Butsuri, 37(3), p.177 - 180, 2017/00

Gel dosimeters are gelated aqueous solutions of radiosensitive substances and useful tools to visualize three-dimensional dose distribution of radiations. A study which uses gel dosimeters to quantify the dose distribution in biological samples is explained. In this study, the measured distribution was compared with the simulation result of PHITS to check the accuracy of Monte Carlo simulation in particle therapy situations. The comparison shows that the measured complex distal edge structure of the dose distribution reflecting the particle transport in inhomogeneous biological sample was reproduced by simulation with a precision of 2 mm difference. The result also shows that gel dosimeters are powerful tools to visualize three-dimensional dose distribution and have potential to be used for various purposes such as quality assurance of treatment beams as well as accuracy check of simulations.

Journal Articles

Performance of Panasonic ZP-1460 electronic personal dosemeter under exposure conditions likely to be found at Fukushima Daiichi Nuclear Power Plant

Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya; Momose, Takumaro

JPS Conference Proceedings (Internet), 11, p.070008_1 - 070008_6, 2016/11

Journal Articles

Effect of heavy ion irradiation on optical property of radiation-crosslinked hydroxypropyl cellulose gel containing methacrylate monomers

Hiroki, Akihiro; Yamashita, Shinichi*; Kimura, Atsushi; Nagasawa, Naotsugu; Taguchi, Mitsumasa

Nuclear Instruments and Methods in Physics Research B, 365(Part B), p.583 - 586, 2015/12

Effects of liner energy transfer (LET) and dose rate on the optical property of polymer gel dosimeters were investigated. The dosimeter prepared by using a radiation-crosslinked hydroxypropyl cellulose gel and methacrylate monomers such as 2-hydroxyethyl methacrylate and nonaethylene glycol dimethacrylate showed the color change from colorless to white with the He, C, Fe ions irradiation. Absorbance of the irradiated dosimeters increased with the dose up to 10 Gy. The absorbance of the dosimeters at the same total dose decreased with increasing dose rate in the range of 0.1 to 6.8 Gy/min. The absorbance decreased in order of He, C, Fe ions, which was in agreement with a change of LET. The increase in LET affected the decrease in the number of polymerization initiator such as OH radical and hydrated electron, resulting in the reduction of the absorbance of the dosimeters.

JAEA Reports

Researches on the characteristics of personal doses after the accident of TEPCO Fukushima Daiichi Nuclear Power Station

Japan Atomic Energy Agency; National Institute of Radiological Sciences*

JAEA-Review 2015-007, 50 Pages, 2015/10

JAEA-Review-2015-007.pdf:3.2MB

The review of the evacuation area due to the accident of TEPCO Fukushima Daiichi Nuclear Power Station has completed and the deregulation has begun in some regions. The authors started this research in order to contribute to the understanding of individual dose that is assumed after the return of the residents. Measurements and evaluation using personal dosemeters were conducted at the typical living locations in the area where the evacuation orders are ready to be lifted and the residence restriction area. So the relationship between air dose and personal dose equivalent there was demonstrated observationally and experimentally. In addition, the estimation of the residents' individual doses in the pattern of their social lives expected after returning home.

Journal Articles

Enhancement in dose sensitivity of polymer gel dosimeters composed of radiation-crosslinked gel matrix and less toxic monomers

Hiroki, Akihiro; Yamashita, Shinichi*; Taguchi, Mitsumasa

Journal of Physics; Conference Series, 573(1), p.012028_1 - 012028_4, 2015/01

BB2014-0610.pdf:0.75MB

 Times Cited Count:4 Percentile:79.08(Engineering, Biomedical)

Polymer gel dosimeters based on radiation-crosslinked hydroxypropyl cellulose gel were prepared, which comprised 2-hydroxyethyl methacrylate (HEMA) and polyethylene glycol dimethacrylate (9G) as less toxic monomers and tetrakis (hydroxymethyl) phosphoniumu chloride (THPC) as an antioxidant. The dosimeters exposed to $$^{60}$$Co $$gamma$$-rays became cloudy at only 1 Gy. The irradiated dosimeters were optically analyzed by using a UV-vis spectrophotometer to evaluate dose response. Absorbance of the dosimeters linearly increased in the dose range from 0 to 10 Gy. The dose sensitivity increased with increasing 9G concentration. The dosimeter with 2 wt% HEMA, 3 wt% 9G, and 0.16 wt% THPC exhibited about 0.04 Abs Gy$$^{-1}$$ of the dose sensitivity. The dose sensitivity of the dosimeters was also enhanced by increment in THPC, reached about 0.06 Abs Gy$$^{-1}$$ at 0.40 wt% THPC.

Journal Articles

RCA/IAEA third external dosimetry intercomparisons in East Asia region

Yamamoto, Hideaki; Yoshizawa, Michio; Murakami, Hiroyuki; Momose, Takumaro*; Tsujimura, Norio*; Kanai, Katsuta*; Cruz-Suarez, R.*

Radiation Protection Dosimetry, 125(1-4), p.88 - 92, 2007/07

 Times Cited Count:0 Percentile:0.01(Environmental Sciences)

The purpose of this paper is to discuss the results of the third intercomparison exercise of external radiation dosimetry organized under the Regional Cooperative Agreement (RCA) in the East Asia region of the International Atomic Energy Agency (IAEA). Twenty five laboratories from 16 member states participated in the exercise. Japan Atomic Energy Research Institute (JAERI) and Japan Nuclear Cycle Development Institute (JNC) arranged the standard irradiation of the participants' dosimeters. The results of the measurements of the irradiated dosimeters for the determination of external doses were satisfactory for all participants, demonstrating good performance in their external dosimetry.

Journal Articles

Calculation of spatial distribution of dose rate for air under 300keV electron beam irradiation using a Monte Carlo code (EGS4-SPG code)

Hakoda, Teruyuki; Hanaya, Hiroaki; Kaneko, Hirohisa; Miyashita, Atsumi; Kojima, Takuji

Radioisotopes, 54(6), p.161 - 168, 2005/06

no abstracts in English

Journal Articles

Relation between neutron dosemeter readings and calibration fields for various workplace spectra

Saegusa, Jun; Tanimura, Yoshihiko; Yoshizawa, Michio

Proceedings of 11th International Congress of the International Radiation Protection Association (IRPA-11) (CD-ROM), 8 Pages, 2004/05

Relationships between dosemeter readings and the true dose equivalents at various workplaces were analyzed. From the analysis, it was shown that depending on the types of dosemeters, there exist a suitable calibration field, and the field differs by the difference of response characteristics of dosemeters. For the precise estimation of dose equivalent, it is important that measurement is carried out under the careful considerations of the difference between neutron spectrum at workplace and at calibration field, as well as the improvement of response characteristics of the dosemeters.

Journal Articles

Absorbed dose rate distribution in 300 keV electron beam irradiation field for waste-gas purification

Hakoda, Teruyuki; Sunaga, Hiromi; Takizawa, Haruki; Hirota, Koichi; Kojima, Takuji

Radioisotopes, 53(2), p.59 - 69, 2004/02

no abstracts in English

Journal Articles

Nuclear decay data used in radiation protection

Endo, Akira

Hoken Butsuri, 38(4), p.308 - 317, 2003/12

no abstracts in English

Journal Articles

Modelling of radiation response of p-Channel SiC MOSFETs

Lee, K. K.; Oshima, Takeshi; Ito, Hisayoshi

Materials Science Forum, 433-436, p.761 - 764, 2003/08

The possibility of applying p-channel SiC MOSFET to dosimeter was investigated. The Source and Drain of SiC MOSFET was formed Al ion implantation at 800 $$^{o}$$C and annealing at 1800 $$^{o}$$C for 1 min in Ar. The gate oxide was fabricated using pyrogenic oxidation. Al electrodes of source and drain is formed Al evaporation and sintering at 850 $$^{o}$$C for 5 min in Ar. Gamma-ray irradiation to the MOSFETs was doned at the rate of 1MR/h at room temperature. As the result, the change of threshold voltage by irradiation is explained to be K$$times$$D$$^{n}$$, where K and n are constants.

JAEA Reports

Development of colored alumilite dosimeter

Obara, Kenjiro; Yagi, Toshiaki; Yokoo, Noriko*; Shibanuma, Kiyoshi

JAERI-Tech 2003-035, 107 Pages, 2003/03

JAERI-Tech-2003-035.pdf:9.45MB

no abstracts in English

Journal Articles

Conversion from tooth enamel dose to organ doses for ESR dosimetry

Takahashi, Fumiaki; Yamaguchi, Yasuhiro

Radiation Risk Assessment Workshop Proceedings, p.71 - 78, 2003/00

Conversion from tooth enamel dose to organ doses against external photon exposure were studied in order to develop a method that can retrospectively estimate organ doses by the Electron Spin Resonance (ESR) dosimetry using tooth samples. Monte Carlo calculations using EGS4 code were performed to obtain dose to tooth enamel and organ doses by using a modified MIRD-type phantom. The Electron Spin Resonance (ESR) dosimetry using tooth samples and dose measurements using thermo-luminescence dosimeters (TLDs) were also carried out to examine dose to teeth region with a realistic physical phantom. A Voxel-type phantom was constructed from CT images of the physical phantom. Monte Carlo calculations with the Voxel-type phantom were performed to verify the results of the experiments and enamel doses calculated by use of the modified MIRD-type phantom. The obtained data are to be useful for the retrospective assessment of individual dose in past exposure events by the ESR dosimetry with tooth enamel.

Journal Articles

Conversion from tooth enamel dose to organ doses for the electron spin resonance dosimetry

Takahashi, Fumiaki; Yamaguchi, Yasuhiro; Iwasaki, Midori*; Miyazawa, Chuzo*; Hamada, Tatsuji*; Saito, Kimiaki

Journal of Nuclear Science and Technology, 39(9), p.964 - 971, 2002/09

 Times Cited Count:6 Percentile:39.54(Nuclear Science & Technology)

Conversion from tooth enamel dose to organ doses was analyzed to establish a method of retrospective individual dose assessment against external photon exposure by the Electron Spin Resonance (ESR) dosimetry. Dose to tooth enamel was obtained by Monte Carlo calculations using a modified MIRD-type phantom. The calculated tooth enamel doses were verified by measurements with thermo-luminescence dosimeters inserted in a physical head phantom. Energy and angular dependences of tooth enamel dose were compared with those of other organ doses. Additional Monte Carlo calculations were performed to study the effects of human model on the tooth enamel dose with a voxel-type phantom, which was based on CT images of the physical phantom. The data derived with the modified MIRD-type phantom were applied to convert from tooth enamel dose to organ doses against external photon exposure in a hypothesized field, where scattered radiations were taken into account. The results indicated that energy distribution of photons incident to a human body should be required to evaluate precisely individual dose by the ESR dosimetry using teeth.

Journal Articles

Analysis of absorbed dose to tooth enamel for ESR dosimetry

Takahashi, Fumiaki; Yamaguchi, Yasuhiro; Saito, Kimiaki; Iwasaki, Midori*; Miyazawa, Chuzo*; Hamada, Tatsuji*; Funabiki, Jun*

Journal of Nuclear Science and Technology, 39(Suppl.2), p.1314 - 1317, 2002/08

An analysis of dose to tooth enamel was carried out to develop a method that can predict the organdose and effective dose by the Electron Spin Resonance (ESR) dosimetry using teeth for external photon exposure. Absorbed dose to tooth enamel were obtained with Monte Carlo calculations using EGS4 code with a mathematical human model, which has a newly defined teeth-part. Experiments were also carried out to investigate the dose at the tooth area with a physical head phantom. The calculated doses to tooth enamel were, however, less than the measured doses with the TLDs for the case of photon incidence from the back of a human body. Then, a computational human model, called a “Voxel (Volume-pixel) type" phantom was constructed based upon a computed topography (CT) image of the physical head phantom used in the experiments.The additional Monte Carlo calculations were performed to verify the results in the experiments with the EGS4 in conjunction with user's code UCPIXEL and the Voxel type phantom.

Journal Articles

Development of new dosimeter using colored alumilite fading

Obara, Kenjiro

Genshiryoku eye, 48(2), p.46 - 48, 2002/02

no abstracts in English

Journal Articles

Evaluation of neutron dosemeter responses to various neutron fields

Saegusa, Jun; Yoshizawa, Michio; Tanimura, Yoshihiko; Yoshida, Makoto

Radioisotopes, 51(1), p.26 - 33, 2002/01

no abstracts in English

184 (Records 1-20 displayed on this page)